Digital I/O for old machines
How machines without a network-capable control join the same live dashboard as the rest of the fleet, and exactly what the connection can and can't see.
What digital I/O is
Digital I/O (digital inputs and outputs) means reading simple on/off electrical signals. Every machine, however old, has them: a run lamp that lights while the machine cuts, a relay that closes at the end of a cycle, an M-code output that pulses when a part is finished. A digital input reads whether each signal is on or off.
The 20-year-old machine that still holds tolerance deserves a place on the dashboard too. Digital I/O brings it into the same live view as the rest of the fleet, honestly labeled for what the connection can and cannot see.
Signal type
- In one line
- On / off, usually 24 V DC or a plain switch closure
Where it comes from
- In one line
- Signals the machine already has: lamps, relays, M-code outputs
Direction
- In one line
- Read-only. Nothing is written to the machine and no logic is changed
Best for
- In one line
- Machines whose control can't share data over a network
| In one line | |
|---|---|
| Signal type | On / off, usually 24 V DC or a plain switch closure |
| Where it comes from | Signals the machine already has: lamps, relays, M-code outputs |
| Direction | Read-only. Nothing is written to the machine and no logic is changed |
| Best for | Machines whose control can't share data over a network |
How an I/O connection works
The machine
- Run lamp / stack light
- Cycle relay
- Part-complete M-code
Digital inputs
on / off per signal
- ThingConnect gateway
- Running / stoppedCycle countsPart counts
A digital I/O connection taps those existing signals, read-only, at the terminals, and the gateway turns them into machine states and counts on the dashboard, exactly as it does for controller-connected machines.
- 1We find the signals on the machine that show running, cycle end and part complete.
- 2Each signal is checked: does it carry its own voltage (wet) or is it a plain switch (dry)?
- 3With the machine powered down, the signals are wired to matching digital inputs.
- 4The gateway turns each on/off change into states and counts, and we check them against the machine running real parts.
Which signals we tap
Run / cycle relay or lamp circuit
- What it yields
- Running vs stopped state, downtime events, utilization.
Cycle start / end pulse
- What it yields
- Cycle times and cycle counts.
Part-complete output (M-code / counter relay)
- What it yields
- Part counts for production tracking.
Alarm lamp (red stack light)
- What it yields
- That the machine is in alarm, without the alarm's name or number.
| Signal tapped | What it yields |
|---|---|
| Run / cycle relay or lamp circuit | Running vs stopped state, downtime events, utilization. |
| Cycle start / end pulse | Cycle times and cycle counts. |
| Part-complete output (M-code / counter relay) | Part counts for production tracking. |
| Alarm lamp (red stack light) | That the machine is in alarm, without the alarm's name or number. |
Wet and dry contacts
Before anything is wired, each signal is checked for what kind it is. Wiring a signal to the wrong input type either reads nothing or can damage the input.
Wet contactHas voltage
The signal carries its own voltage, for example a 24 V DC lamp or a PLC output. It is wired to an input that measures that voltage.
Dry contactPlain switch
A relay or switch that simply opens and closes, with no voltage of its own. The input supplies the voltage and reads whether the contact is closed.
Isolated inputs keep the machine's wiring electrically separate from the monitoring side, so a fault on one can't reach the other.
A practical example: the stack light
Many old machines have a stack light, the column of coloured lamps on top. Its lamps already show the machine's state, so tapping them gives a useful picture with very little wiring.
Green on
- Usually means
- Running a program
- Shown on the dashboard as
- Running
Amber on
- Usually means
- Waiting, idle or cycle finished
- Shown on the dashboard as
- Idle
Red on
- Usually means
- Alarm or emergency stop
- Shown on the dashboard as
- Alarm (without the alarm name)
All off
- Usually means
- Machine switched off
- Shown on the dashboard as
- Off
| Lamp | Usually means | Shown on the dashboard as |
|---|---|---|
| Green on | Running a program | Running |
| Amber on | Waiting, idle or cycle finished | Idle |
| Red on | Alarm or emergency stop | Alarm (without the alarm name) |
| All off | Machine switched off | Off |
Lamp meanings vary by machine builder, so we confirm them on each machine before going live.
The honest limits
An I/O connection sees on/off, not meaning. It cannot tell why the machine stopped, which program was running, or whether an override is turned down: signals that exist only inside the control. Two consequences follow:
- Operators supply the why.Stop reasons on I/O machines come from a two-tap operator prompt, not from alarm codes, so the reason list must be short and in the operators' own words.
- OEE is partial. Availability and counts are solid; performance depth (override drift, in-cycle pauses) is not visible. We show what is measured and never estimate the rest into a prettier number.
Digital I/O compared with a controller connection
Running / stopped
- Digital I/O
- Yes
- Controller connection (FOCAS, OPC UA, MTConnect, FTP)
- Yes
Cycle and part counts
- Digital I/O
- Yes, where a signal exists
- Controller connection (FOCAS, OPC UA, MTConnect, FTP)
- Yes, from the control's own counter
Alarm state
- Digital I/O
- On / off only
- Controller connection (FOCAS, OPC UA, MTConnect, FTP)
- Alarm number and message
Program running
- Digital I/O
- No
- Controller connection (FOCAS, OPC UA, MTConnect, FTP)
- Yes
Feed and spindle overrides, spindle load
- Digital I/O
- No
- Controller connection (FOCAS, OPC UA, MTConnect, FTP)
- Yes, depending on the control
Wiring at the machine
- Digital I/O
- Yes, at the signal terminals
- Controller connection (FOCAS, OPC UA, MTConnect, FTP)
- No, an Ethernet cable only
| Data | Digital I/O | Controller connection (FOCAS, OPC UA, MTConnect, FTP) |
|---|---|---|
| Running / stopped | Yes | Yes |
| Cycle and part counts | Yes, where a signal exists | Yes, from the control's own counter |
| Alarm state | On / off only | Alarm number and message |
| Program running | No | Yes |
| Feed and spindle overrides, spindle load | No | Yes, depending on the control |
| Wiring at the machine | Yes, at the signal terminals | No, an Ethernet cable only |
When to use digital I/O
Old control with no Ethernet or data interface
- Our recommendation
- Digital I/O
Control has Ethernet, but the data option isn't installed and adding it isn't worth it
- Our recommendation
- Digital I/O
Non-CNC equipment: presses, washers, manual machines
- Our recommendation
- Digital I/O
FANUC with Ethernet
- Our recommendation
- FOCAS
Newer control with OPC UA or MTConnect
| Situation | Our recommendation |
|---|---|
| Old control with no Ethernet or data interface | Digital I/O |
| Control has Ethernet, but the data option isn't installed and adding it isn't worth it | Digital I/O |
| Non-CNC equipment: presses, washers, manual machines | Digital I/O |
| FANUC with Ethernet | FOCAS |
| Newer control with OPC UA or MTConnect | OPC UA or MTConnect |
The right mix: on a typical Indian floor most machines carry network-capable controls and connect natively — FANUC over FOCAS above all — while the oldest few join over I/O. Be wary of any vendor proposing I/O boxes for a whole fleet whose controls could have spoken for themselves.
Is it safe for the machine?
Changing the machine
- How it's handled
- Monitoring doesn't change programs, settings or how the machine runs. Only existing signals are read.
Electrical safety
- How it's handled
- Wiring is done at the signal terminals with the machine powered down, and each signal is matched to the right input type.
Machine faults
- How it's handled
- Isolated inputs keep the machine's circuits separate from the monitoring side.
| Concern | How it's handled |
|---|---|
| Changing the machine | Monitoring doesn't change programs, settings or how the machine runs. Only existing signals are read. |
| Electrical safety | Wiring is done at the signal terminals with the machine powered down, and each signal is matched to the right input type. |
| Machine faults | Isolated inputs keep the machine's circuits separate from the monitoring side. |
Frequently asked questions
Yes. Machines whose controls cannot speak over a network can still report run/idle state and count pulses through digital I/O signals — typically taken from existing relays, stack-light circuits, or spare M-code outputs. It is shallower than a controller connection, but it puts the whole fleet on one dashboard.
Reliably: running vs stopped, cycle start/end pulses, and a part-count signal where one exists. It cannot report alarms by name, program identity, override positions, or spindle load — those exist only inside the control. We label I/O-connected machines accordingly so nobody mistakes inferred data for controller truth.
No. The connection reads signals that already exist — a relay closing, a lamp circuit energizing, an M-code output pulsing. Nothing is written to the machine and no logic is changed. The wiring is done at the signal terminals, machine powered down, in under an hour per machine in most cases.
Almost never. If the control can speak — FANUC over FOCAS, or a machine with MTConnect or OPC UA — the native connection reads far more, with no wiring at all. I/O is the fallback for machines that have no other way in, not a shortcut for machines that do.
A wet contact carries its own voltage, such as a 24 V DC lamp or relay output. A dry contact is a plain switch closure with no voltage of its own; the input supplies it. Each needs the matching input type, which we check on every signal before wiring.
See it live