FOCAS: FANUC's CNC data interface
What FOCAS is, how it works, what it can read from a FANUC control, and how ThingConnect uses it to monitor FANUC machines.
What FOCAS is
FOCAS(FANUC Open CNC API Specifications) is FANUC's own interface for reading data out of its CNC controls over the network. A FANUC control with FOCAS answers requests on a network port (8193 by default), and software asks it for things like run status, the running program, part count and alarms. The answer comes straight from the control, not from a sensor guessing at what the machine is doing.
Made by
- In one line
- FANUC, for its own CNC controls
Connection
- In one line
- Ethernet (TCP/IP), or HSSB, FANUC's fibre-optic link to a PC card, on older set-ups
Default port
- In one line
- TCP 8193; can be set between 5001 and 65535 on the control
Read or write
- In one line
- The library can do both. Monitoring only reads.
Clients at once
- In one line
- A few. FANUC's 0i-D manual allows up to five FOCAS2 clients on the built-in Ethernet port
| In one line | |
|---|---|
| Made by | FANUC, for its own CNC controls |
| Connection | Ethernet (TCP/IP), or HSSB, FANUC's fibre-optic link to a PC card, on older set-ups |
| Default port | TCP 8193; can be set between 5001 and 65535 on the control |
| Read or write | The library can do both. Monitoring only reads. |
| Clients at once | A few. FANUC's 0i-D manual allows up to five FOCAS2 clients on the built-in Ethernet port |
Looking to monitor FANUC machines rather than learn the protocol? See FANUC machine monitoring.
How FOCAS works
FOCAS is a request-and-answer interface. FANUC supplies a software library; a program on a PC or gateway uses it to open a connection to the control, ask for a piece of data, and get the control's answer back.
- 1The client opens a connection to the control's IP address on the FOCAS port (8193 by default).
- 2It sends a request, such as "what is the machine doing" or "which alarms are active".
- 3The control answers from its own memory: the same values its screens show.
- 4The client repeats the requests it needs and closes the connection when done.
Key features of FOCAS
Native to FANUC
- What it means
- Built by FANUC for its own controls; no translation box between the software and the control
Deep data
- What it means
- Status, program and line, counters, alarms, overrides, spindle and axis load, timers, macro variables, program text
Ethernet or HSSB
- What it means
- Newer controls use the built-in Ethernet port; older set-ups may use HSSB to a PC card
No extra hardware on newer controls
- What it means
- Controls with a built-in Ethernet port need only a network cable
Read and write
- What it means
- The library can also write. Monitoring uses read requests only
FANUC only
- What it means
- FOCAS does not work with other brands. Mixed fleets use OPC UA, MTConnect, FTP or digital I/O for the rest
| Feature | What it means |
|---|---|
| Native to FANUC | Built by FANUC for its own controls; no translation box between the software and the control |
| Deep data | Status, program and line, counters, alarms, overrides, spindle and axis load, timers, macro variables, program text |
| Ethernet or HSSB | Newer controls use the built-in Ethernet port; older set-ups may use HSSB to a PC card |
| No extra hardware on newer controls | Controls with a built-in Ethernet port need only a network cable |
| Read and write | The library can also write. Monitoring uses read requests only |
| FANUC only | FOCAS does not work with other brands. Mixed fleets use OPC UA, MTConnect, FTP or digital I/O for the rest |
FOCAS1 and FOCAS2, and which controls support them
FOCAS1Older controls
The original library, for older FANUC controls and for connections over HSSB, FANUC's fibre-optic link between the control and a PC card.
FOCAS2Current
The current library, used over Ethernet with today's controls such as the 0i-D, 0i-F and the 30i/31i/32i family.
For a plant, the difference rarely matters. What matters is whether a machine has Ethernet and FOCAS switched on, which varies machine to machine. Published sources don't agree on exactly which older series fall under which library, so we confirm it per control in the site survey.
0i
- Examples
- 0i-F, 0i-D
- Usual connection
- FOCAS2 over the built-in Ethernet port
30i / 31i / 32i
- Examples
- 30i-B, 31i-B
- Usual connection
- FOCAS2 over the built-in Ethernet port
16i / 18i / 21i
- Examples
- 16i-MB, 18i-TB, 21i-MB
- Usual connection
- Ethernet board or HSSB; checked per machine
Older series
- Examples
- Series 0, 15, 16, 18, 21; Power Mate
- Usual connection
- FOCAS1, often over HSSB or an Ethernet board; checked per machine
| Control family | Examples | Usual connection |
|---|---|---|
| 0i | 0i-F, 0i-D | FOCAS2 over the built-in Ethernet port |
| 30i / 31i / 32i | 30i-B, 31i-B | FOCAS2 over the built-in Ethernet port |
| 16i / 18i / 21i | 16i-MB, 18i-TB, 21i-MB | Ethernet board or HSSB; checked per machine |
| Older series | Series 0, 15, 16, 18, 21; Power Mate | FOCAS1, often over HSSB or an Ethernet board; checked per machine |
What FOCAS reads from a FANUC control
Everything below is what ThingConnect reads today. Exactly what a control returns depends on its generation and options, which is why we check each machine before quoting a rollout.
Machine state
- Examples
- Running, stopped, feed hold, mode (auto, MDI, edit, jog), emergency stop, alarm
- What it gives you
- Live status and every downtime event, timed by the control
Program
- Examples
- Running program number and name, main program, the line (N number) being executed
- What it gives you
- Every stop and every part tied to the job and the line it stopped on
Production
- Examples
- Part count and target (the control's own counters, or a counter your program keeps), operating and cutting time
- What it gives you
- Parts against plan, and cutting time against powered-on time
Alarms and messages
- Examples
- Active alarms with number, type and message; operator messages
- What it gives you
- Downtime that names its own cause
Cutting
- Examples
- Feedrate, spindle speed, feed, rapid and spindle override, active tool number, active G-codes
- What it gives you
- Overrides left turned down and slow running, made visible
Load
- Examples
- Spindle load and axis (servo) load
- What it gives you
- Abnormal cutting and tool wear show up early
Programs on the control
- Examples
- A copy of the program text
- What it gives you
- A record of which version of a program made which parts
Tool life
- Examples
- The macro variables your tool-life program keeps
- What it gives you
- Remaining life per tool
Controller
- Examples
- Control type, series, software version, axis names
- What it gives you
- Fleet records
| Data | Examples | What it gives you |
|---|---|---|
| Machine state | Running, stopped, feed hold, mode (auto, MDI, edit, jog), emergency stop, alarm | Live status and every downtime event, timed by the control |
| Program | Running program number and name, main program, the line (N number) being executed | Every stop and every part tied to the job and the line it stopped on |
| Production | Part count and target (the control's own counters, or a counter your program keeps), operating and cutting time | Parts against plan, and cutting time against powered-on time |
| Alarms and messages | Active alarms with number, type and message; operator messages | Downtime that names its own cause |
| Cutting | Feedrate, spindle speed, feed, rapid and spindle override, active tool number, active G-codes | Overrides left turned down and slow running, made visible |
| Load | Spindle load and axis (servo) load | Abnormal cutting and tool wear show up early |
| Programs on the control | A copy of the program text | A record of which version of a program made which parts |
| Tool life | The macro variables your tool-life program keeps | Remaining life per tool |
| Controller | Control type, series, software version, axis names | Fleet records |
Practical example: a FANUC 0i-F machining centre
What a monitoring screen built on FOCAS shows for one machine, at one moment. The values below are an example, not a customer's data.
Status
- Example value
- Running, AUTO mode
- Read from
- The control's status
Program
- Example value
- O1234, line N220
- Read from
- The program being executed
Part count
- Example value
- 152 of 400
- Read from
- The control's part counter and target
Spindle
- Example value
- 6,000 rpm, 38% load
- Read from
- Spindle speed and load
Feed override
- Example value
- 80%
- Read from
- The override switch on the operator panel
Alarm
- Example value
- None active
- Read from
- The control's alarm list
| Item | Example value | Read from |
|---|---|---|
| Status | Running, AUTO mode | The control's status |
| Program | O1234, line N220 | The program being executed |
| Part count | 152 of 400 | The control's part counter and target |
| Spindle | 6,000 rpm, 38% load | Spindle speed and load |
| Feed override | 80% | The override switch on the operator panel |
| Alarm | None active | The control's alarm list |
When the machine stops on an alarm, the same screen shows the alarm number and text, and the stop is recorded against program O1234 without anyone typing it.
FOCAS compared with other ways to connect a FANUC
FOCAS, direct
- What it is
- Software reads the control through FANUC's library over Ethernet
- Good for
- The deepest data, with nothing added to the control
FANUC MTConnect Server
- What it is
- A FANUC option that publishes control data as MTConnect; listed for 0i-D, 0i-F and 30i/31i/32i-A/B
- Good for
- Plants standardising on MTConnect across brands
FANUC MT-LINKi
- What it is
- FANUC's own collection software, running on a PC server
- Good for
- FANUC-centred monitoring set up through FANUC
- What it is
- Signals wired from the machine (running, part done)
- Good for
- Older FANUC controls without Ethernet
| Option | What it is | Good for |
|---|---|---|
| FOCAS, direct | Software reads the control through FANUC's library over Ethernet | The deepest data, with nothing added to the control |
| FANUC MTConnect Server | A FANUC option that publishes control data as MTConnect; listed for 0i-D, 0i-F and 30i/31i/32i-A/B | Plants standardising on MTConnect across brands |
| FANUC MT-LINKi | FANUC's own collection software, running on a PC server | FANUC-centred monitoring set up through FANUC |
| Digital I/O | Signals wired from the machine (running, part done) | Older FANUC controls without Ethernet |
Across brands, FOCAS sits beside OPC UA, MTConnect and FTP. Each machine is connected the deepest way it supports, and all land on one dashboard.
How ThingConnect uses FOCAS
Your plant
FANUC control
FOCAS · TCP port 8193
ThingConnect gateway
reads every FANUC control in the plant
- ThingConnect cloud
- Live dashboardOEE reportsDowntime reports
- 1The control's Ethernet port is cabled to the plant network, and FOCAS answers on its port.
- 2The ThingConnect gateway in your plant connects to each FANUC control and reads its data.
- 3The gateway sends the data to the ThingConnect cloud over one secure outbound connection.
- 4You see live status, OEE and downtime on any screen, and reports by shift and day.
Is FOCAS safe on a production machine?
Yes. Monitoring doesn't change programs, settings or how the machine runs.
Will it change my machine?
- What actually happens
- No. Monitoring only reads.
Will it slow the control down?
- What actually happens
- No. The machine runs exactly as before.
Will the machine be on the internet?
- What actually happens
- No. The control talks only to the gateway inside your plant. The gateway connects out to the cloud; nothing connects in.
Do I need FANUC software or a PC at the machine?
- What actually happens
- No MT-LINKi server and no PC per machine.
| Concern | What actually happens |
|---|---|
| Will it change my machine? | No. Monitoring only reads. |
| Will it slow the control down? | No. The machine runs exactly as before. |
| Will the machine be on the internet? | No. The control talks only to the gateway inside your plant. The gateway connects out to the cloud; nothing connects in. |
| Do I need FANUC software or a PC at the machine? | No MT-LINKi server and no PC per machine. |
Setup and checks: what your maintenance team does
1. Network
- What to do
- Cable the control's Ethernet port to the plant network and give it a fixed IP address.
2. FOCAS port
- What to do
- On a 0i-F: SYSTEM, then the + soft key, EMBED PORT, then FOCAS2. Check the TCP port (8193 by default) and set the UDP port to 0. Power the control off and on after a change.
3. Quick check
- What to do
- From a laptop on the same network, ping the control's IP address. If it answers, the network side is ready.
4. Hand over
- What to do
- Our team connects the gateway and checks the live data against the control's own screens.
| Step | What to do |
|---|---|
| 1. Network | Cable the control's Ethernet port to the plant network and give it a fixed IP address. |
| 2. FOCAS port | On a 0i-F: SYSTEM, then the + soft key, EMBED PORT, then FOCAS2. Check the TCP port (8193 by default) and set the UDP port to 0. Power the control off and on after a change. |
| 3. Quick check | From a laptop on the same network, ping the control's IP address. If it answers, the network side is ready. |
| 4. Hand over | Our team connects the gateway and checks the live data against the control's own screens. |
Menu names differ slightly between control series. Nothing is installed on the control, and no machine is stopped for the setup.
Common FOCAS problems, and what we do about them
The machine is on, but the connection is refused
- What's happening
- FOCAS or the Ethernet function is off on the control, or it's on a different port.
- What we do
- Our alert says "port closed", so maintenance knows to check the control's Ethernet settings, not the network.
The machine is reachable, but data stops
- What's happening
- A FANUC control accepts only a few FOCAS connections at once, and other software may be using them.
- What we do
- The alert says "FOCAS failing" rather than "offline", so the cause is clear.
The part count never goes up
- What's happening
- Some machines don't update the control's own part counter. The program counts parts in a macro variable instead.
- What we do
- We read that macro variable as the part count.
The machine shows running during a pallet change
- What's happening
- While the control waits on an M-code (such as a pallet change), it still reports itself as running.
- What we do
- We mark those waits as idle, with the reason shown.
Some data is missing on one control but not another
- What's happening
- Not every control supports every FOCAS request.
- What we do
- That machine shows everything its control does support.
| What you see | What's happening | What we do |
|---|---|---|
| The machine is on, but the connection is refused | FOCAS or the Ethernet function is off on the control, or it's on a different port. | Our alert says "port closed", so maintenance knows to check the control's Ethernet settings, not the network. |
| The machine is reachable, but data stops | A FANUC control accepts only a few FOCAS connections at once, and other software may be using them. | The alert says "FOCAS failing" rather than "offline", so the cause is clear. |
| The part count never goes up | Some machines don't update the control's own part counter. The program counts parts in a macro variable instead. | We read that macro variable as the part count. |
| The machine shows running during a pallet change | While the control waits on an M-code (such as a pallet change), it still reports itself as running. | We mark those waits as idle, with the reason shown. |
| Some data is missing on one control but not another | Not every control supports every FOCAS request. | That machine shows everything its control does support. |
No FOCAS on a machine? Older machines, or controls without Ethernet, join the same dashboard through digital I/O. Newer equipment can also connect over OPC UA or MTConnect.
Frequently asked questions
FOCAS (FANUC Open CNC API Specifications) is FANUC's own interface for reading data out of its CNC controls over the network. Software that uses it can read machine status, the running program, part count, alarms, overrides, spindle load and more, directly from the control.
TCP port 8193 by default. It can be changed on the control (FANUC allows 5001 to 65535), so we confirm it machine by machine during installation.
FOCAS1 is the original library for older FANUC controls, including connections over HSSB, FANUC's fibre-optic link to a PC card. FOCAS2 is the current library, used over Ethernet with the 0i-D, 0i-F and 30i/31i/32i families. Which one a control uses is confirmed per machine in the site survey.
ThingConnect needs no MT-LINKi server and no PC at the machine. What a control needs is Ethernet and the FOCAS function switched on, which varies machine to machine, so we check each one in the site survey.
The FOCAS library can write as well as read. Monitoring with ThingConnect doesn't change programs, settings or how the machine runs.
Older controls, or controls without Ethernet, may not support it. Those machines join the same dashboard through a digital I/O connection, which gives running status and part count.
See it live